fiberglass Parshall flume installed in concrete channel Under laboratory conditions Parshall Flumes can be expected to operate accurately to within +/-2%. 

To achieve optimal accuracy:

  • The site must be suitable for the flume
  • The incoming flow must be well conditioned
  • The flume must be installed accurately
  • The flume and upstream / downstream channels must be kept clear of vegetative growth, trash, debris, and silt
  • The interior flow surfaces must be kept clean and free of algal growth and corrosion
  • Downstream conditions should not submerge the flume

​In practice, accuracies better than +/-5% are difficult to achieve and total system accuracies (flume, flow meter, etc.) are typically +/-10%.

These conditions, however, generally apply to all flumes in experiencing similar conditions and should not be taken solely as a reflection on the nature of the Parshall Flume.